Visado: when certification by the professional body is mandatory
Certification by the professional body is voluntary except for a closed list of work. In building, the list includes the execution project and the final certificate. The basic design is not on it and a permit can be applied for with it.

- Execution project
- Final certificate
- Legalisation
- Demolition without explosives
In this article
- The short version
- Voluntary as a rule, mandatory by list
- The work that must be certified
- The basic design, the permit and the self-declaration
- What the professional body checks and what it does not
- When, where and the exceptions
- Common cases in a practice
- Before taking it to the professional body
- Where Archelo helps
- Frequently asked questions
The short version
This guide explains which of an architect’s work must be certified by the professional body, why the basic design need not be, what the body checks and what it does not, when and where certification happens, the exceptions and a table of the usual cases. Everything comes from the consolidated text of Royal Decree 1000/2010, article 13 of the Professional Bodies Act 2/1974, the Building Act and the Spanish building code in the official gazette. For Andalusia it draws on the LISTA regulation published in the regional gazette (BOJA).
Voluntary as a rule, mandatory by list
Since 2009, article 13 of the Professional Bodies Act starts from certification being voluntary. Bodies for technical professions certify work when the client asks, including a public authority acting as such. They also certify when the Government requires it by royal decree. To require it there must be a direct link between the work and people’s safety. Certification must also be the most proportionate means of control. The Act adds that professional bodies cannot impose certification themselves or through their statutes.
Royal Decree 1000/2010, in force since 1 October 2010, is that decree. Its article 2 makes certification mandatory only for the work it lists. Its repealing provision voids any rule of equal or lower rank requiring certification for other work, as well as conflicting internal rules of the professional bodies. If a piece of work is not on the list, certification is the client’s choice.
The work that must be certified
Of the nine items in article 2, four concern an architect’s work. The other five cover blasting, explosives, fireworks and mining.
| Work | When it is mandatory | RD 1000/2010 |
|---|---|---|
| Construction design for a building | When the works require a project under article 2.2 of the LOE | Art. 2(a) |
| Final completion certificate for a building | For the same works, with the changes made and the list of inspections as annexes | Art. 2(b) |
| Construction design and completion certificate for a legalisation | When they must be submitted in the legalisation procedure under planning rules | Art. 2(c) |
| Demolition project without explosives | When the applicable planning rules require one | Art. 2(d) |
The key is article 2.2 of the LOE, which decides which works need a project: new construction except minor single-storey structures of technical simplicity that are neither residential nor public, interventions on existing buildings that alter their architectural configuration (full ones, partial ones that substantially change the exterior composition, the volume or the structural system and those that change the main uses) and interventions on protected buildings that affect what is protected. That is why a retail-to-residential change of use needs a certified construction design even when the works are light.
Under section II.3.3 of annex II to Part I of the building code, the final completion certificate carries as annexes a description of the changes made during the works with the developer’s agreement together with the list of inspections carried out with their results. Certification of the certificate covers that documentation.
The basic design, the permit and the self-declaration
The basic design is not on the list. It can be certified if the client asks. It is not mandatory. Part of the confusion comes from the building code itself: its 2006 annex III defines the basic design as sufficient to apply for a permit once the required certification has been obtained. That definition predates Royal Decree 1000/2010, whose closed list does not include the basic design.
In Andalusia the LISTA regulation says so expressly. Its article 299.1(a) allows a building permit to be applied for with the basic design. Works cannot start, however, until the construction design has been submitted, certified where national rules require it. Article 300 repeats that projects may be certified voluntarily and that certification is mandatory where national rules say so. And article 293.2 attaches the self-declaration to the required technical project, certified when those same rules demand it.
Some councils ask, with the basic design, for a certificate from the professional body confirming the architect’s standing instead of certification. It is worth checking each council’s bylaw or portal. The full application file is covered in the guide to building permit documents.
What the professional body checks and what it does not
Article 13.2 of the Professional Bodies Act sets what certification checks, at a minimum:
- The author’s identity and professional standing, against the register of members.
- The formal correctness and completeness of the documents, under the rules that apply to the work.
The certification must state clearly what it covers and which points it has checked. It covers neither fees and contract terms nor the technical review of the professional content of the work. In other words, the body does not check whether the structure is correctly calculated or whether the design meets the building code. That responsibility stays with the author.
If damage arises from certified work for which the author is liable, the body is secondarily liable and only for defects it should have spotted when certifying and that relate directly to what it certified (article 13.3). Where certification is mandatory its cost must be reasonable, not excessive or discriminatory. Bodies publish their prices (article 13.4).
When, where and the exceptions
- Before submission. Mandatory certification is obtained before the work is submitted to the authority. It can never be added afterwards (article 6.2).
- Once. If the project is completed with partial projects or other technical documents, certifying the whole once, at one body, is enough: the one for the main discipline. Each part need not be certified (article 3).
- At the body for the main discipline, that of the professional responsible for the whole. Where the professional organisation has regional bodies, any of them can certify (article 5).
- The completion certificate, at a body competent in site direction or in construction management. Either one is enough (article 5.1).
- Membership. Mandatory certification can only be refused for not being a member when membership is compulsory for that work (article 6.3).
What matters in practice is the order. The document has to be final before it is signed and certified, because any page added afterwards breaks the electronic signature and falls outside the certification. Header, footer and cover go on before the signature.
In public works, if the project goes through the contracting authority’s project supervision office, its report replaces certification (article 4.1). The contracting authority may also waive it when its procurement process already checks the author’s identity and standing and the formal correctness of the work (article 4.2). The LISTA regulation includes both routes in its article 300.2.
For work not on the list, the central Government does not require certification in its contracts, unless the Council of Ministers agrees an exception (sole additional provision). Professionals from another EU state working in Spain under the freedom to provide services must certify in the same cases as Spanish ones (article 7).
Common cases in a practice
The table applies the article 2 list to everyday commissions. Anything not on it is voluntary, although the client or the council may ask for certification.
| Commission | Mandatory certification? | Why |
|---|---|---|
| New detached house: construction design | Yes | New residential building, requires a project (LOE 2.2(a)) |
| The same house: basic design for the permit | No | The basic design is not on the article 2 list |
| Retail-to-residential change of use | Yes, the construction design | Changes the main use (LOE 2.2(b)) |
| Interior refurbishment not touching structure, façade or use | No, unless the LOE requires a project | Does not alter the architectural configuration |
| Partial works affecting protected elements | Yes, the construction design | LOE 2.2(c) |
| Completion certificate for works that require a project | Yes | Art. 2(b) |
| Legalisation of works already built | Yes, if the procedure requires a project and certificate | Art. 2(c) |
| Demolition without explosives with a project | Yes | Art. 2(d) |
| Energy performance certificate, building assessment report, valuation | No | Not on the list |
Before taking it to the professional body
- Decide under article 2.2 of the LOE whether the works require a project. That decides whether the construction design must be certified.
- The final document, with cover, index, header and footer, before signing.
- Every author’s electronic signature after the document is closed. Certification after the signatures.
- Partial projects and technical annexes in the same file, for a single certification.
- Certify before submitting to the council, never after.
- In the completion certificate, the description of changes and the list of inspections as annexes.
- Check whether the council asks for anything with the basic design: voluntary certification or a certificate of the architect’s standing.
Where Archelo helps
Archelo helps you prepare what goes for certification: it checks that the documents the procedure asks for are there and that they agree, orders and numbers them, adds the header and footer to every page and prepares the cover with its index, all before you sign. So what you sign and certify is the final document. See it on AI for architects.
This article is for information only and does not replace checking the current text of Royal Decree 1000/2010, the other rules cited, each professional body’s statutes and fees or each council’s bylaw.
Frequently asked questions
Does the basic design have to be certified?
No. Article 2 of Royal Decree 1000/2010 does not include it in its closed list. It can be certified if the client asks. Work cannot start without the certified execution project when the works need a project under the LOE.
Which of an architect’s jobs must be certified?
Four: the execution project and the final certificate when the works need a project under article 2.2 of the LOE, those required for a legalisation, and the demolition project without explosives where planning rules provide for it.
Can a project be certified after it has been submitted?
Not if certification is mandatory. Article 6.2 of Royal Decree 1000/2010 requires it before the work is submitted to the authority and rules out certifying it afterwards.
Does the professional body check that the project meets the building code?